80KA三相電源防雷箱

80KA三相電源防雷箱

80KA三相電(dian)(dian)源防雷箱KSJ-380B/80應(ying)用范圍電(dian)(dian)信(xin),智能(neng)建筑,機場(chang),工(gong)廠,電(dian)(dian)力(li)。鐵路等低壓配(pei)電(dian)(dian)系(xi)統(tong)(tong),電(dian)(dian)器,電(dian)(dian)子設備和設備內互聯系(xi)統(tong)(tong)過電(dian)(dian)壓及(ji)高(gao)壓靜電(dian)(dian)的防護,主,分(fen)配(pei)電(dian)(dian)系(xi)統(tong)(tong)中(zhong)的過電(dian)(dian)壓浪涌保護。

2,產品特點(dian):◎ 放(fang)電通流量大,保(bao)護水平高,安(an)全,可靠(kao),維護方便(bian)

◎ 本產品防(fang)雷單元(yuan){每(mei)相}采用矩陣式多(duo)芯片組合電路結(jie)構(gou)

◎ 每相線路設(she)計采用(yong)均流技術,大通流量設(she)計

◎ 每一(yi)放(fang)電(dian)單元設(she)有(you)熱(re)熔(rong)保(bao)護和(he)過流保(bao)護

◎ 工作狀態指示﹝正常(chang)為(wei)(wei)綠(lv)燈,失(shi)效或故障為(wei)(wei)紅(hong)燈)

◎ 配(pei)有雷(lei)電計數器,能(neng)高錄大于3KA以上的(de)雷(lei)擊事(shi)件次(ci)數

◎ 結(jie)構(gou)美觀,安裝方便

3,避(bi)雷器(qi)安(an)裝要求(qiu)說明(ming):

1、SPD應用(yong)于(yu)主分配電(dian)(dian)(dian)系(xi)統為220V或(huo)380V第一(yi)、二、三級雷電(dian)(dian)(dian)防護,并聯安裝(zhuang)在建筑(zhu)物配電(dian)(dian)(dian)箱或(huo)機房的電(dian)(dian)(dian)源(yuan)進線端,配35mm電(dian)(dian)(dian)氣導軌,可采(cai)用(yong)凱文(wen)連(lian)接(jie)方式。安裝(zhuang)前必須切(qie)斷電(dian)(dian)(dian)源(yuan),嚴禁帶電(dian)(dian)(dian)操作。

2、安(an)裝(zhuang)時(shi)請(qing)根據安(an)裝(zhuang)示(shi)意圖(tu)所示(shi)連接,其(qi)中L為相線(xian),N為零線(xian),PE為地線(xian),切勿(wu)錯接。安(an)裝(zhuang)完成后,合(he)上(shang)自動斷(duan)路器開關,檢查工作(zuo)狀態是否正(zheng)常。

3、在AC供配電系(xi)統中(zhong),為防止SPD老化短路造(zao)成系(xi)統故障,SPD安(an)裝(zhuang)線路上應(ying)有過(guo)電流(liu)保護器(qi)件,并選(xuan)用(yong)有劣化顯示功能的SPD;

4、避雷(lei)器應盡量安(an)裝在(zai)被保護(hu)設(she)(she)備內(nei),若無法(fa)安(an)裝在(zai)被保護(hu)設(she)(she)備內(nei)時,必須(xu)先將SPD安(an)裝在(zai)安(an)裝盒內(nei),再安(an)裝在(zai)附近的墻上或靠(kao)近被保護(hu)設(she)(she)備的其它地方;

5、SPD連(lian)接導線長(chang)度不宜超過(guo)0.5m,接地引線應盡量避免與電源(yuan)線緊挨平行(xing)布設(she),并宜粗、短(duan)、直;

6、當SPD1至SPD2的線距(ju)長度(du)小于(yu)10米時(shi), SPD2至SPD3的線距(ju)長度(du)小于(yu)5米時(shi),需(xu)要(yao)在SPD之間應(ying)加裝退耦電感;

7、各級電(dian)源(yuan)SPD必須(xu)安裝在交(jiao)流配電(dian)設備的交(jiao)流輸入(ru)端,宜采用凱文接線方式連(lian)接(將室內接地(di)(di)(di)匯集線與(yu)接地(di)(di)(di)引(yin)入(ru)線連(lian)接處斷開(kai),斷開(kai)處的兩端分(fen)別單獨引(yin)線接至(zhi)SPD的接地(di)(di)(di)端);

8、80KA三相電(dian)源(yuan)(yuan)防雷箱和空氣開關(guan)與35mm的(de)標(biao)準導(dao)軌(gui)可靠(kao)固定,電(dian)源(yuan)(yuan)一級SPD連(lian)接(jie)導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)經不(bu)得小(xiao)于(yu)16mm2,接(jie)地導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)徑不(bu)得小(xiao)于(yu)25mm2;電(dian)源(yuan)(yuan)二級SPD連(lian)接(jie)導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)經不(bu)得小(xiao)于(yu)10mm2,接(jie)地導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)徑不(bu)得小(xiao)于(yu)16mm2;電(dian)源(yuan)(yuan)三級SPD連(lian)接(jie)導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)經不(bu)得小(xiao)于(yu)6mm2,接(jie)地導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)徑不(bu)得小(xiao)于(yu)10mm2;信號避(bi)雷器連(lian)接(jie)導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)經不(bu)得小(xiao)于(yu)2.5mm2,接(jie)地導(dao)線(xian)(xian)(xian)(xian)(xian)線(xian)(xian)(xian)(xian)(xian)徑不(bu)得小(xiao)于(yu)6mm2;

9、電源SPD應以最短、直路徑(jing)接(jie)地,SPD的接(jie)地線應避(bi)免出現“V”形和(he)“U”形彎(wan)(wan),連(lian)線的彎(wan)(wan)曲角度不得小(xiao)于90°,且接(jie)地線必須綁扎固(gu)定(ding)好,松緊適中;

10、SPD連接線的走(zou)線要美觀,特別是直線、轉彎、連接頭,保證SPD整潔美觀,連接牢固可靠(kao);